Home > Gas Heating Controls
Gas Heating Controls
  • WHITE RODGERS GAS VALVES
  • HONEYWELL GAS VALVES
  • POWER GENERATORS
  • THERMOCOUPLES
  • HOT SURFACE IGNITERS
  • PILOT BURNERS
  • PILOT CONTROLS
  • IGNITION MODULES
  • INTEGRATED FURNACE CONTROLS
  • FAN LIMIT CONTROLS
HVAC Parts by Source1, Honeywell, White Rodgers, AO Smith, Tyco and much more.

Call 800.227.9922 Monday-Friday / 8AM-5PM pacific time for more information

Browse by sub-category below or you can scroll down until you see all Gas Heating Control Parts.
Conversion Kits - Natural Gas and Liquefied Petroleum

Conversion Kits - Natural Gas and Liquefied Petroleum

Natural Gas to Liquefied Petroleum

Liquefied Petroleum to Natural Gas
Fan Limit Controls - Honeywell L4064 Fan & Limit Controls

Honeywell L4064 Fan & Limit Controls

For control of high limit and fan motor in all types of forced air heating systems.
Features:
• Three wiring terminal options available for easy installation: push-in receptacles for stripped wire, female receptacles for 1/4”
male flag connectors, and field add-on screw terminals.
• Controls adapt to many competitive mounting holes in replacement applications.
• Available in a variety of fan and high limit setting ranges.
• Super Tradeline models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect
wiring from field abuse.
Specifications:
Application: Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop factory
set at 200ºF (93ºC). Replaces L4064A,B,E.
Fan-on Range: 65ºF to 215ºF (18ºC to 102ºC
Fan-off Range: 50ºF to 200ºF (10ºC to 96ºC)
Pilot duty: 0.25 A @ 0.25 to 12 Vdc, 2 A @ 24 VAC
Dimensions: 5-3/8”H x 3”W x 2”D (137 mm H x 76 mm W x 51 mm D) excluding element.
Mounting: Rigid bracket
Differential Temperature: 25ºF (14ºC), fixed.
Approvals: UL Listed; CSA Certified.
Fan Limit Controls - Honeywell L4064W Fan & Limit Controls

Honeywell L4064W Fan & Limit Controls

For control of high limit and fan motor in all types of forced air heating systems.
Features:
• Three wiring terminal options available for easy installation:
• push-in receptacles for stripped wire, female receptacles for 1/4-in. male flag connectors, and field add-on screw terminals.
• Controls adapt to many competitive mounting holes in replacement applications.
• Available in a variety of fan and high limit setting ranges.
• SUPER TRADELINE models include deluxe case with mounting adapters for easy installation and strain relief bushings to
rotect wiring from field abuse.
Fan Limit Controls - White Rodgers Fan & Limit Controls for Universal Replacement

White Rodgers Fan & Limit Controls for Universal Replacement

Single element type for applications with narrow space limitations. Regulates fan or blower operation and acts as high limit
safety control.
Features:
• Designed to be interchangeable with other flush mounted, single element fan and limits.
• Slotted mounting holes for easy installation.
• Long Terminal screws for wiring—Junctions can be made on terminal block.
• Limit switch has “universal” contact structure capable of handling millivolts to 240 VAC.
• Limit switch has adjustable stop to limit maximum setting—Shipped at 200° F (94° C).
• Dial has individual pointers for fan cut-in and cut-out settings.
• Removable solid copper jumper between fan and limit switches.
• Summer fan switch for ventilation without changing control settings. Has same fan and limit switch mechanism.
• C.S.A. Certified and U.L. Recognized.
Gas Valve - Honeywell V800 Standing Pilot Gas Valve

Honeywell V800 Standing Pilot Gas Valve

Used on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, and pressure regulator, pilot gas filter and flowadjustment, pressure tapping, and thermocouple connector. V800 is used on 24V systems.

Features:
• Include pilot flow adjustment screw.
• Easy to install, adjust and service; all adjustments and connections are accessible from top of control.
• Add separate energy cutoff (ECO) where codes call for dual safety shutoff.
• Complete safety shutoff on pilot flame failure.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.
• ECO connector for V800 models. Part No. 392451-1.

Specifications:
Type: Single Stage
Ignition Type: Standing Pilot
Type of Gas: Natural or LP
Body Pattern: Straight-through, multi-tapped with 1/2" right and left outlets plugged
Note: No side outlets on S1-VA800A1476.
Pressure Ratings (psi): 1/2 psi
Pressure Ratings (kPa): 3.5 kPa
Pilot Gas Outlet: Compression fitting for 1/4” OD tubing
Pressure Tapping: 1/8” NPT with plug
Electrical Ratings: 24 VAC
Frequency: 60 Hz
Anticipator Setting: .2 A
Temperature Range (F): 32°F to 175°F
Temperature Range (C): 0°C to 79°C
Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Dimensions (in.): 4-3/4”H x 4-1/16”W x 3-3/16”D
Dimensions (mm): 121 mm H x 103 mm W x 81 mm D
Approvals: American Gas Association IAS AGA Design Certified; File No. L2025003, CGA Design Certified;
File No. L2025003, UL Component Recognized; Underwriters Laboratories Inc UL Component Recognized.
Gas Valve - Honeywell VR8200 Continuous Pilot Dual Automatic Combination Gas Valves

Honeywell VR8200 Continuous Pilot Dual Automatic Combination Gas Valves

Combination gas controls for use in 24 VAC, gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. Both include: 1/2” x 3/8” reducer bushing; 39369014 bag assembly—3/4” straight flange with O ring, screws and wrench; Q340 (39”) thermocouple with adapters; and 393691 Natural to LP gas conversion kit. VR8200A2132 does not contain the thermocouple. The VR8200A2124 does.

• Control includes safety shutoff, a manual valve, two automatic operators, servo pressure regulator and pilot
adjustment.
• Compact size.
• Provide two automatic valves.
• Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is
interrupted.
• Meet codes requiring dual safety shutoff.
• All adjustments, wiring connections and pilot outlet are accessible from top of control.
• Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in
gas supply pressure.
• Compatible with ECO connector.
• VR8200 controls replace the following Honeywell and competitive combination gas controls for applications requiring a minimum capacity of 20 cfh and a maximum capacity of 200 cfh.
— Honeywell V800A and VR800A models
— White Rodgers 36C03/01 series
— Robertshaw 7000BER (700-400) series
— Robertshaw 7200BER (720-400) series
— ITT B57 and B59 series
— Essex SX242N

Approval Bodies:
American Gas Association Design certified: File No. L2025006.
Canadian Gas Association Design certified: File No. L2025006.
Underwriters Laboratories Inc. component recognized: File No. MH5323.

Lite-Rite (Off-Pilot-On) lighting sequence.
Mounting: 0° to 90° in any direction from the upright position of gas control knob, including vertically.
Body Pattern: Straight-through with 1/2" inlets and outlets.
Pilot Gas Outlet: Compression fitting for 1/4” OD tubing.
Pressure Tapping: 1/8" NPT with plug
Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure.
Ambient Temperature Range: VR8200A: 0°F to 175°F [-18°C to +79°C].

Electrical Data:
Supply Voltage: 24 VAC, 60 Hz.
Wiring Connections: Combination screw and 1/4" male quick-connects.
Thermostat Heat Anticipator Setting: 0.5 A.
Gas Valve - Pilot Burner - Honeywell Pilot Burner for Natural Gas

Honeywell Pilot Burner for Natural Gas

Nonprimary-aerated combination pilot burner and igniter. Used with the S86, S860, S8610, or S8670 in intermittent
pilot systems.
Features:
• Includes pilot burner with bracket, ceramic insulated Kanthal flame rod/spark igniter and ground strap.
Specifications:
Type of Gas: Natural
Direction of Front Tip: (F) Front
Tip Style: Single
Aeration: Non-primary
Leadwire Temperature Ratings (C): Max. at electrode tip: 968°C
Includes: 1/4" cc inlet fitting and mounting adapter
Gas Valve - SV9501 SmartValve System Gas Valve

SV9501 SmartValve System Gas Valve

The SmartValveTM System Controls provide intermittent pilot gas ignition sequencing, pilot flame sensing, and both
pilot and main gas control functions in a single control. They are directly compatible with the Q3450 or Q3480
intermittent pilot burners used with the original controls on many gas fired heating appliances.
Features:
• Suitable for a wide range of gas-fired appliances including residential furnaces, rooftop furnaces, residential boilers,
unit heaters, infrared heaters, space heaters and commercial cooking units.
• Replaces some SV9500, SV9501 and SV9502 SmartValve™ System models.
• Ignition sequence includes timed trial for ignition.
• Pilot gas outlet
Specifications:
Flame Sense: Electrode
Ignition System Type: Intermittent hot surface pilot ignition
Ignition Sequence: Intermittent pilot
Ignition Source: Pilot
Ignition Trials to Lockout: Continuous retry
Ignition Trial Time: 90 sec.
Flame Failure Response Time: 1.6 sec. @ 3 μA
Prepurge: None
Body Pattern: Straight-through
Opening Characteristics: Standard opening
Ambient Temperature Range: –40° to +175°F (–40° to +79°C)
Electrical Ratings: 24 VAC
Frequency: 60 Hz/50 Hz
Approvals: American Gas Association IAS, IAS Design Certified: C2030017
Gas Valve - VR8205A Direct Ignition Dual Automatic Combination Gas Valves

VR8205A Direct Ignition Dual Automatic Combination Gas Valves

Combination gas control for use with hot surface/ direct spark systems in 24 VAC, gas-fired appliances with
capacities from 20 to 200 cfh. Control includes manual valve, two automatic operators, and servo pressure regulator.
Used with S89E,F and S87C,D Control Modules. Provides dual-seated safety shutoff. Solenoid operated first
automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm operated second
automatic valve opens under control of the regulator; closes if gas or power supply is interrupted. Meets codes
requiring dual safety shutoff. Adjustments and wiring connections are accessible from top of the control. American
Gas Association and Canadian Gas Association design certified. On-Off lighting sequence. Mounting: 0° to 90° in any direction from the upright position of the gas control knob, including vertically.
Body Pattern: Straight-through. Includes: 1/2” x 3/8” reducer bushing; 39369014 bag assembly—3/4” straight flange with O ring, screws and
wrench; and 393691 Natural to LP gas conversion kit.
Gas Valve - VR8300A Dual Standing Pilot Gas Valve

VR8300A Dual Standing Pilot Gas Valve

Combination gas control for use in 24 VAC, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features:
• Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
• Compact size.
• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is
interrupted.
• Meets codes requiring dual safety shutoff.
• Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas
conversion kit also available.
• All adjustments, wiring connections and pilot outlet are accessible from top of control.
• Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in
gas supply pressure.
• Compatible with ECO connector.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.
Specifications:
Type: Single Stage
Ignition Type: Standing Pilot
Type of Gas: Natural
Body Pattern: Straight through with integral tapping; with flange
Opening Characteristics (standard, step): Standard
Pressure Ratings (psi): 1/2 psi
Pressure Ratings (kPa): 3.5 kPa
Pressure Regulator setting (psi): 3.5” W.C.
Pressure Regulator setting (kPa): 0.87 kPa
Pilot Gas Outlet: Compression fitting for 1/4” OD tubing
Pressure Tapping: 1/8” NPT with plug
Electrical Connections: 1/4” male quick-connects
Electrical Ratings: 24 VAC
Frequency: 60 Hz
Anticipator Setting: 0.7 A
Temperature Range (F): 0°F to 175°F
Temperature Range (C): -18°C to +79°C
Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Dimensions (in.): 5-3/8”H x 4-1/16”W x 2-11/16”D
Dimensions (mm): 135 mm H x 104 mm W x 69 mm D
Approvals: American Gas Association IAS AGA Design Certified: File No. L2025006; Canadian Gas Association
CGA Design Certified: File No. L2025006; Underwriters Laboratories Inc UL Component Recognized.
Gas Valve - VR8304 Dual Intermittent Pilot Gas Valve

VR8304 Dual Intermittent Pilot Gas Valve

Combination gas control for use in 24 VAC, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.
Features:
• Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
• Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.
• Compact size.
• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is
interrupted.
• Meet codes requiring dual safety shutoff.
• Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion
kit also available.
• All adjustments, wiring connections and pilot outlet are accessible from top of control.
• Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas
supply pressure.
• Compatible with ECO connector.
• ON-OFF lighting sequence.
Specifications:
Type: Single Stage
Ignition Type: Intermittent Pilot
Type of Gas: Natural
Body Pattern: Straight-through
Opening Characteristics (standard, step): Standard
Pressure Ratings (psi): 1/2 psi
Pressure Ratings (kPa): 3.5 kPa
Pressure Regulator setting (psi): 3.5” W.C.
Pressure Regulator setting (kPa): 0.87 kPa
Pilot Gas Outlet: Compression fitting for 1/4” OD tubing
Pressure Tapping: 1/8” NPT with plug
Electrical Connections: 1/4” male quick-connects
Electrical Ratings: 24 VAC
Frequency: 60 Hz
Anticipator Setting: 0.7 A
Temperature Range (F): -40°F to +175°F
Temperature Range (C): -40°C to +79°C
Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Dimensions (in.): 5-3/8”H x 4-1/16”W x 2-11/16”D
Dimensions (mm): 135 mm H x 104 mm W x 69 mm D
Approvals: American Gas Association IAS AGA Design Certified: File No. L2025007; Canadian Gas Association CGA
Design Certified: File No. L2025007; Underwriters Laboratories Inc UL Component Recognized.
Honeywell Aquastat Controls

Honeywell Aquastat Controls

Immersion type controls for limiting or regulating temperatures of liquids in boilers or tanks.
Features:
• Totally enclosed Micro Switch™ snap-acting switches operate on temperature rise to setpoint.
• Visible control point scale and external adjustment screw permit easy setting.
• Horizontal or vertical insertion of the sensing element, Direct or well immersion of the sensing element.
• Models available for strap-on mounting.
• Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications.
• Tradeline models include well adapter and tube of heat-conductive compound.
• Select models have wells.
Specifications:
Electric Ratings (full load): 8.0 A @ 120 VAC;5.1 A @
240 VAC
Electrical Ratings (locked rotor): 48.0 A @ 120
VAC;30.6 A @ 240 VAC
Electrical Ratings (millivolt): 0.25 A @ 0.25 to 12 Vdc
Insulation Depth: 1-1/2" to 3" (38 mm to 76 mm)
Bulb Size: 3/8" X 2-7/8" (10 mm x 73 mm) copper
Approvals: UL Component Recognized: File number
MP466, Vol. Sec. 1, Guide number MBPR2; CSA Certified:
File number LR95329-1; AGA Certified: L4006A
Case Dimensions: 5-5/8”H x 2”W x 2-1/8”D (143 mm H x 51
mm W x 54 mm D)
Mounting: L4008E1156—Horizontal or vertical;
L6006A1145—horizontal
Honeywell Aquastat Relays

Honeywell Aquastat Relays

Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.
Features:
• High limit opens burner circuit only.
• Include transformer and accessory terminals for adding a remote low limit controller.
• Case available for horizontal or vertical mounting.
Requires a 24 VAC thermostat with heat anticipator set at 0.2A.
• TRADELINE models include well adapter, tube of heat conductive compound and range stops.
Specifications:
Application: High Limit
Operating Range, High Limit (F): 120°F to 240°F
Operating Range, High Limit (C): 54°C to 116°C
Differential Temperature (F): 8°F fixed
Setpoint Temperature Range (F): 240°F
Setpoint Temperature Range (C): 116°C
Switching Action SPST: High Limit & Circulator
Anticipator Setting: 0.2 A
Maximum Operating Pressure (psi): Immersion Well: 255 psi
Maximum Operating Pressure (kPa): Immersion Well: 1757
kPa
Electrical Ratings (burner AFL): Line Voltage: 7.4 A @ 120
VAC; 3.7 A @ 240 VAC
Electrical Ratings (burner ALR): Line Voltage: 44.4 A @ 120
VAC; 22.7 A @ 240 VAC
Electrical Ratings (burner millivolt): 0.25 A @ 1/4 to 12 Vdc
Electrical Ratings (circulator AFL): 7.4 A @ 120 VAC; 3.7 A
@ 240 VAC
Electrical Ratings (circulator ALR): 44.4 A @ 120 VAC; 22.2
A @ 240 VAC
Voltage: 120 VAC
Frequency: 60 Hz
Capillary Length (in.): 4-1/2"
Capillary Length (mm): 114 mm
Insulation Depth (in.): 1-1/2" to 3" less well.
Insulation Depth (mm): 38 mm to 76 mm less well
Humidity Ratings (%RH): 0 to 95% RH, noncondensing
Maximum Ambient Temperature (F): 150°F with 1.2 A
24 V load; 77 F with 1.4 A 24 V load
Maximum Ambient Temperature (C): 66°C with 1.2 A
24 V load; 25 C with 1.4 A 24 V load
Electrical Connections: Quick-Connect / Screw
Approvals, Underwriters Laboratories Inc
UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide
No.MBPR2.
Approvals, Canadian Standards
Association Certified: File No. LR1620, Guide No. 400-
E-O
Hot Surface Igniter - Direct-Brand Universal Silicon Nitride Hot Surface Igniters

Direct-Brand Universal Silicon Nitride Hot Surface Igniters

A Universal silicon nitride hotsurfaceingniter kit you can handle with the greasiest of hands.

The replacement for over 100 types of older igniters.

Upgrade to a durable nitride for your furnace, boiler, pool or water heater.
Hydronic Heating Controls - Honeywell Zone Valves

Hydronic Heating Controls - Honeywell Zone Valves

Sweat less end switch zone valve, necessary for temperature control of a single zone in a hydronic heating system.
Features:
• Use with thermostat with special heat anticipator designed for best performance when used with the V8043 Zone Valve.
• Require 24 V power source.
Specifications:
Body Pattern: 2-Way
Pipe Connections: Sweat
Valve Electrical Rating (Voltage,
Frequency): 24 VAC, 50/60 Hz
Valve Electrical Connections (in.): 18" leads
Valve action: Spring return to close
Valve Dimensions (in.): Valve: 4”H, 3-1/2”W, 2-3/8”D
Valve Dimensions (mm): Valve: 101 mm H x 90 mm W x 60
mm D
Approvals, Underwriters Laboratories Inc
UL Listed: Models V8043A,B,E,J & V8044A,B,E; UL
Component Recognized: V8043F
Approvals, Canadian Standards Association
CSA Certified: File no. LR95329-1
Approval Bodies:
American Gas Association Design certified: File No. L2025006.
Canadian Gas Association Design certified: File No. L2025006.
Underwriters Laboratories Inc. component recognized: File No. MH5323.

Lite-Rite (Off-Pilot-On) lighting sequence.
Mounting: 0° to 90° in any direction from the upright position of gas control knob, including vertically.
Body Pattern: Straight-through with 1/2" inlets and outlets.
Pilot Gas Outlet: Compression fitting for 1/4” OD tubing.
Pressure Tapping: 1/8" NPT with plug
Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure.
Ambient Temperature Range: VR8200A: 0°F to 175°F [-18°C to +79°C].

Electrical Data:
Supply Voltage: 24 VAC, 60 Hz.
Wiring Connections: Combination screw and 1/4" male quick-connects.
Thermostat Heat Anticipator Setting: 0.5 A.
Ignition Modules - Direct Spark Non-Integrated Spark Ignition Module

Direct Spark Non-Integrated Spark Ignition Module

Features:
• Color LED Indicator for Diagnostics
• Direct and Indirect Flame Sense
Electrical Rating
• Input 18 to 30 VAC, 25 VAC nominal
• Max. Input Current: @ 25 VAC: 0.2A + MV @ 25°C
Relay Load Ratings
Main Valve Relay: 25 VAC, 1.5 Amp Max.
Pilot Valve Relay: 25 VAC, 1.5 Amp Max.
Ignition Modules - For Silicon Carbide, Non-Integrated HSI Systems

For Silicon Carbide, Non-Integrated HSI Systems

Replaces ALL White-Rodgers 50E47-xxx modules and virtually all competitive silicon carbide, non-integrated modules.
Features:
• Program Keys for Easy Customization
• Tri-Color LED Indicator for Diagnostics
• Direct and Indirect Flame Sense
Electrical Rating
• Input 18 to 30 VAC, 25 VAC nominal
• Max. Input Current @ 25 VAC; 200mA @ 25°C
Relay Load Settings
Valve Relay: 1.5 amps @ 25 VAC 60 Hz .6pf
Ignitor Relay: 6.0 amps @ 120 VAC 60 Hz resistive
Ignition Modules - Honeywell S8610U Universal Intermittent Pilot Module

Honeywell S8610U Universal Intermittent Pilot Module

Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers and other
heating appliances.Provides ignition sequence, flame monitoring and safety shutoff (max. 90 sec.) for intermittent pilot
central furnaces and heating appliances.
Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition
trial/delay sequence is repeated until the appliance lights or call for heat is removed.
For use with natural or LP gas.
For use in single rod or dual rod/remote sense applications.
Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve
rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended.
Functional equivalent of S86, S90, S8600 and S8610 modules.
Includes cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing
cable.
Improved enclosure design protects internal circuitry from moisture or dust accumulation. Includes remote reset, and
automatic vent damper plug. Replaces most of the following intermittent pilot modules:
— Honeywell S86, S90, S8600 and S8610
— Robertshaw SP715, SP715A, SP735, SP735A, SP735L
— Johnson GSA, G60, G65, G67, G600, G770 Refer to S8610 specification sheet for a complete list of model numbers.
APPROVAL BODIES:
American Gas Association Design certified.
Canadian Gas Association Design certified.
Underwriters Laboratories Inc. Component recognized.
AMBIENT TEMPERATURE RATING: –40°F to +165°F [–40°C to +74°C].
FLAME FAILURE RESPONSE TIME: 0.8 sec. At 1.0 mA flame current.
WIRING CONNECTIONS: 1/4" male quick connect terminals, including ignition terminal (3/16" male quick-connect sense
terminal).
ELECTRICAL RATINGS: Voltage and Frequency – 24V (nominal), 60Hz. Current rating – 0.2A
             RUNNING INRUSH
PILOT        1.0A         10.0A
MAIN          2.0A         20.0A
NOTE: Maximum ambient temperature is 175°F [79°C] if main valve relay load is 1.0A or less.
THERMOSTAT HEAT ANTICIPATOR SETTING: 0.2A plus pilot valve rating plus main valve rating. Spark Generator
Output – 13 kV peak at 25 pf load.
Ignition Modules - Intermittent Pilot Non-Integrated Spark Ignition Module

Intermittent Pilot Non-Integrated Spark Ignition Module

Features:
• Color LED Indicator for Diagnostics
• Direct and Indirect Flame Sense
Electrical Rating
• Input 18 to 30 VAC, 25 VAC nominal
• Max. Input Current: @ 25 VAC: 0.2A + MV + PV @ 25°C
Relay Load Ratings
Main Valve Relay: 25 VAC, 1.5 Amp Max.
Pilot Valve Relay: 25 VAC, 1.5 Amp Max.
Ignition Modules - Multi-Stage Carbide and Nitride HSI Systems 21M51U-843 For 3-Speed PSC Motors

Multi-Stage Carbide and Nitride HSI Systems 21M51U-843 For 3-Speed PSC Motors

21M51U-843 For 3-Speed PSC Motors
Replaces: White-Rodgers 50M51-242 and All 50M61-XXX’s Two-Stage HSI Systems with 80V or 120V Ignitor.
Includes: Specifications:
•Ignition Control Module Electrical Ratings [@ 77°F (25°C)]
• Universal 120V Nitride Ignitor Kit – 21D64-2 Input Voltage: 24 VAC, 60 Hz (Class II transformer req’d)
• Installation Instructions and OEM Cross-Reference Nom. Input Current @ 24 VAC: 530 mA + MV
Relay Load Ratings
Features: Gas Valve Relays: 1.5 amps @ 24 VAC, 60 Hz
• 120 VAC Ignitor Output Inducer Relays: 2.2 FLA – 3.5 LRA @ 120 VAC
• 120 VAC Two-Speed Inducer Output Circulator Relays: 14.5 FLA – 25.0 LRA @ 120 VAC
•120 VAC Humidifier Output Humidifier Load: 1.0 amp max. @ 120 VAC
• 120 VAC Electronic Air Cleaner Output Electronic Air Cleaner Load: 1.0 amp max. @ 120 VAC
•120 VAC 3-Speed PSC Circulator Output Ignitor Relay: 4.0 amps max. @ 132 VAC, 60 Hz
• 2-Stage Gas Valve Output Flame Current Requirements
•Fuse Protection – 3 Amp Minimum current to insure flame detection: 0.3 μa DC*
•Furnace Status LED – Tri-Color (Green, Red and Amber) Maximum current for non-detection: 0.1 μa DC*
•Heat Fan OFF Delay (Dipswitch Selectable) Maximum allowable leakage resistance: 100 M ohms
• Fan ON Delay for Cooling *Measured w/ DC microammeter in the flame probe lead
• Auto Second Stage Delay (Dipswitch Selectable Mode) Operating Temperature Range
• Historical Fault Retrieval by Pushbutton -40° to 175°F (-40° to 80°C)
•YLO, Y, W1, W2, R, G, C, TWIN Terminals Humidity Range
• Pressure Switch Inputs and Monitoring 5% to 93% relative humidity (non-condensing)
• Flash Microprocessor with Non-Volatile Memory Timing Specifications (@ 60 Hz)
• Flame Current Measurement Points Flame Failure Response Time: 2.0 sec. max.
Gases Approved
Natural, Manufactured, Mixed, LP, and LP/Air Mixtures
Dimensions
5.25" W x 8" H x 1.25" D
Ignition Modules - Multi-Stage Carbide and Nitride HSI Systems 21V51U-843 For Variable Speed Motors

Multi-Stage Carbide and Nitride HSI Systems 21V51U-843 For Variable Speed Motors

21V51U-843 For Variable Speed Motors
Replaces: All White-Rodgers 50V51-XXX’s and 50V61-XXX’s Two-Stage HSI Systems with 80V or 120V Ignitor.
Includes:
• Ignition Control Module Specifications:
• Wiring Harnesses for Amana/Goodman Electrical Ratings [@ 77°F (25°C)]
• Universal 120V Nitride Ignitor Kit – 21D64-2 Input Voltage: 24 VAC, 60 Hz (Class II transformer req’d)
• Installation Instructions and OEM Cross-Reference Nom. Input Current @ 24 VAC: 595 mA + MV
Features: Relay Load Ratings
• 120 VAC Ignitor Output Gas Valve Relays: 1.5 amps @ 24 VAC, 60 Hz
•120 VAC Two-Speed Inducer Output Inducer Relays: 2.2 FLA – 3.5 LRA @ 120 VAC, 60 Hz
•120 VAC Humidifier Output Humidifier Load: 1.0 amp max. @ 120 VAC, 60 Hz
•120 VAC Electronic Air Cleaner Output Elect. Air Cleaner Load: 1.0 amp max. @ 120 VAC, 60 Hz
• 2-Stage Gas Valve Output Ignitor Relay: 4.0 amps max. @ 132 VAC, 60 Hz
• 16-Pin Variable Speed Circulator Output Flame Current Requirements
• OEM Application – Dipswitch Selectable Minimum current to insure flame detection: 0.3 μa DC*
• Fuse Protection – 3 Amp Maximum current for non-detection: 0.1 μa DC*
• Furnace Status LED – Tri-Color (Green, Red and Amber) Maximum allowable leakage resistance: 100 M ohms
• CFM LED – (Green) *Measured w/ DC microammeter in the flame probe lead
• Heat Fan OFF Delay (Dipswitch Selectable) Operating Temperature Range
• Fan ON Delay for Cooling -40° to 175°F (-40° to 80°C)
• Auto Second Stage Delay (Dipswitch Selectable Mode) Humidity Range
• Historical Fault Retrieval by Pushbutton 5% to 93% relative humidity (non-condensing)
• YLO, Y, W, W2, R, G, C, O, BK/DS/Dehum Terminals Timing Specifications (@ 60 Hz)
• Pressure Switch Inputs and Monitoring Flame Failure Response Time: 2.0 sec. max.
• Flash Microprocessor with Non-Volatile Memory Gases Approved
• Flame Current Measurement Points Natural, Manufactured, Mixed, LP, and LP/Air Mixtures
Dimensions
5.25" W x 8" H x 1.25" D
Ignition Modules - Single Stage Carbide and Nitride HSI Systems

Single Stage Carbide and Nitride HSI Systems

Replaces: Virtually All White-Rodgers and Competitive
Single Stage Carbide and Nitride HSI Systems –Including Honeywell S9200U1000.
Includes:
• Ignition Control Module
• 9 Quick-Select/Quick-Connect Wiring Harnesses
• Universal Nitride Ignitor Kit – 21D64-2
• Installation Instructions and OEM Cross-Reference
Features:
• 3 Fan Speeds – Cool, Low Heat & High Heat Speeds (Terminal Connections)
• Color-Coded (Labeled) Thermostat Connection – For Quick Helpful Selection
• System Diagnostics, with Fault Recall (Stored)
• Cover Label – Displays Diagnostic Table
• Red LED Light – Used for Diagnostic Flash Codes
• Low Voltage – Fuse Protection – 3A Replaceable Automotive Type
• Humidifier & Electronic Air Cleaner Connections (Optional)
Specification:
Electrical Rating: [@ 77°F (25°C)]
Input Voltage: 25 VAC 50/60 Hz
Max. Input Current @ 25 VAC: 0.45 amp
Relay Load Ratings: Valve Relay:1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)
Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC
Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC
Flame Current Requirements
Minimum current to insure flame detection: 1 μa DC*
Maximum current for non-detection: 0.1 μa DC*
Maximum allowable leakage resistance: 100 M ohms
*Measured with a DC microammeter in the flame probe lead
Operating Temperature Range -40° to 176°F (-40° to 80°C)
Mounting
Surface mount multipoise
Timing Specifications (@ 60 Hz)
Maximum
Flame Establishing Time: 0.8 sec
Flame Failure Response Time: 2.0 sec
Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixtures are all approved for use.
Relay Load Rating
Main Valve Relay: 1.5A @ 25 VAC 60 Hz
Hot Surface Ignition: 120 VAC
Ignition Modules - Universal Silicon Carbide Integrated Ignition Module

Universal Silicon Carbide Integrated Ignition Module

The 50A55-843 employs a microprocessor to continually monitor, analyze and control the proper operation of the gas
burner, inducer and fan.
Electrical Ratings at 77°F (25°C):
Input Voltage: 25 VAC 50/60 Hz
Maximum Input Current: at 25 VAC 0.45 amp
Operating Temperature: –40° to 176°F (–40° to 80°C)
Humidity: 5% to 93% relative humidity (non condensing)
Pilot Controls - White Rodgers Pilot Relite Control

White Rodgers Pilot Relite Control

Ignition control generates spark pulses to ignite pilot gas. The relite control generates sparks until a pilot flame is
sensed between the electrode and ground. The relite control detects a flame through “flame conduction” (ability of a
flame to conduct a current). When flame current is sensed between the electrode and pilot burner ground, the relite
control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant
the flame goes out.
Features:
• A.G.A. Design certified and C.G.A. certified.
Source 1 Hot Surface Igniters

Source 1 Hot Surface Igniters

Source 1's Norton hot surface igniters are made of high purity recrystallized silicon carbide to provide reliable ignition
in a variety of heating systems.
• Replaces Carrier, Lennox, Rheem, Trane,and others
• Can reach ignition temperature(s) in 17 seconds
• 18-gauge nickel chrome lead wires enclosed with high-temperature fiberglass insulation
• Compare to Robertshaw R 41-400 Series
See following table for cross-reference information.
Source 1 Timesaver Silicon Nitride Igniters

Source 1 Timesaver Silicon Nitride Igniters

Compare to White-Rodgers 21D64-2 and Honeywell Q3200U1004, Replaces over 100 Silicon Carbide igniters
Features:
• Robust Ignitor Design—for Longer Life and Fewer Callbacks
• Universal Bracket Fits Most Furnaces—
• Reduces Inventory
• Easy to Install
•3-Year Warranty
Specifications
• Electrical Rating
Input 102-132 VAC, 60Hz
Max. Load Current 3.0 A @ 132 VAC, 25 degrees C
• Timing Rating 17 Seconds Minimum
Kit Includes:
• Silicon Nitride Igniter with 15.5" Leads
• One “Universal” Mounting Bracket and Screw
• Mounting Adaptor Bracket
• 2 Ceramic Wire Nuts
• Updated Manufacturer Cross-Reference
• Instruction Booklet

Replaces over 100 types of igniters. See Below.

FITS MODELS: Amana: 10735003A, 20165703A, 20165703, 201657-03, Model 601, American Road Equipment: 201W, Arco Air: 1096048, 1380680, Armstrong Air: 38322B001, Carlin: 87197S, Carrier/Bryant/Payne*: LH33ZS001, LH33ZS001A, LH33ZS002, LH33ZS002A, LH33ZS003, LH33ZS003A, LH33ZS004, Clair Bros.: C-238, C-242, Coleman: 1474-051, 1474-052, Comfort Maker: 1096048, Detroit Radiant:: 201D, DMO Ind.: 20834, Dornback Furnace: 271W, Ducane: 20015201, Enerco Tech: 10399, Evcon: 1474-051, 1474-052, Evcon Coleman: 025-32625-000, Goodman: 0230K00001, B1401009, B140109S, B1401015S, B1401018, B1401018S, HB Smith: 50018, Heil: 1096048, Honeywell: Glowfly (Q3200U), Hupp Industries: 09050, Intercity: 1009604, 1096048, Majestic: 75-92-104, 75-92-105, Metzger: 201N, 201W, Modine: 5H76032A, Mor-Flo: 3200618, 511-330-193, Nordyne: 105141000, 632-0770, 632-0880, Norton/St. Gobain: 201, 201D, 201J, 201K, 201L, 201M, 201N, 201R, 201W, 271, 271M, 271N, 271NM, 271P, 271W, Raypak: 600915, Rheem/RUUD: 62-22441-01, 62-22868-02, 62-22868-82, 62-22868-93, Roberts Gordon: 90434300, 90436600, Robertshaw: 41-402, 41-403, 41-404, 41-405, 41-407, 41-408, 41-409, 41-410, 41-411, 41-412, 41-413, 41-414, 41-418, Snyder General 1380654, 1380672, 130680, Superior Fireplace: 94851, Tempstar: 1096048, Trane: 340039P01, B138196P01, B144676P01, B144676P02, B340039P01, IGN00023, IGN00026, IGN00030, IGN00034, Viessman: 9302-094, Wayne Home Equipment: 62821-001, 62821-002, Weil McLain: 511-330-139, 511-330-188, 511-330-190, 511-330-193, White LB: 120-07549, White-Rodgers: 767A-301, 767A-303, 767A-306, 767A-310, 767A-311, 767A-350, 767A-353, 767A-354, 767A-357, 767A-361, 767A-364, 767A-365, 767A-366, 767A-370, 767A-373, 767A-375, 767A-376, 767A-377, 767A-378, 767A-382, 767A-383, 767A-384, Williamson: 09050, York/Luxaire/Coleman/Guardian/Winchester/Atlas-Butler: 025-27766-000, 025-27774-000, 025-29043-000, 025-29050-000, 025-32625-000
Thermopile - Honeywell Q313 Thermopile Generator

Honeywell Q313 Thermopile Generator

Q313 Thermopile Generator contains multiple thermocouples connected in series to increase the millivoltage output.
The power generated is sufficient to operate an automatic millivolt gas control system, independent of any outside
power source.
Features:
• Push-in clip, split nut, and adapter assembly for easy pilot burner installation.
• Spade or quick-connect terminals available for millivolt gas control connections.
• Male nut connector for Pilotstat® safety control power units.
• Available in a variety of lead lengths.
Specifications:
Voltage 750 mV
Connection Type Spade Terminals
Open Circuit Output (mV) 600 mV to 750 mV
Temperature Ratings (F) Hot Junction 1400 F
Temperature Ratings (C) Hot Junction 760 C
Temperature Ratings (F) Cold Junction 780 F
Temperature Ratings (C) Cold Junction 416 C
Used With Q314, Q324, Q327, Q377, Q379,
Q382 Pilot Burners
VR8345 Universal Electronic Ignition Combination Gas Control

VR8345 Universal Electronic Ignition Combination Gas Control

• For use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-fired appliances, with
capacities from 30 to 415 cfh.
• For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas.
• Control includes: manual valve, two automatic operators, pressure regulator (3.5" WC), pilot adjustment, pilot plug and
ignition adapter, two 3/4” x 1/2” NPT reducer bushings and one 1/2” x 3/8” NPT bushing.
• Replaces virtually any IP, HSI or DSI gas control.
• Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/HIS jumper.
• Internal inlet screen blocks contaminants in gas line from entering valve.
Body Pattern: Straight-through with 3/4” x 3/4” inlet and outlet.
Dimensions: 5-3/8” H, 4-1/16” W, 2-11/16” D (135 mm H, 104 mm W, 69 mm D)
Approvals: AGA Design Certified: File number L2025007; CGA Design Certified: File number L2025007.
White Rodgers 750 Millivolt Power Generator

White Rodgers 750 Millivolt Power Generator

Provides power for 750 millivolt self-generation control systems.
Features:
• For replacement of similar screw-in type generators now in field or for use with type E31- 12 pilot burner.
• G01A-332 has 36 inch armored cable leads with split-spade terminals.
• PG9 Adapter included with each G01A-332.
White Rodgers Gas Water Heater Valves

White Rodgers Gas Water Heater Valves

For replacement of standard gas water heater controls with built-in E.C.O. (Energy Cut Off).
Features:
• Automatic shut-off of main and pilot gas in.
• the event of pilot failure.
• Pilot gas cock with safe lighting feature.
• Pilot gas filter.
• Temperature adjustment.
• Manifold pressure tap.
• Built-in E.C.O. (Energy Cut Off) non-cycling high limit.
• A.G.A. Certified.
Specifications:
Inlet Size: — 1/2” NPT.
Outlet Size: — 1/2” Inverted Flare
Outlet Adapter Fittings (furnished with controls noted
below): 1/2” inverted flare x 3/8” NPT reducer adapter. 1/2”
x 1/2” inverted flare outlet extension adapter (F26-0021)
Mounting: 3/4” NPT, 1-1/4”, shank length, 4-1/2” bulb
insertion length
Pilot Connection: 1/4” compression fitting for use with
Natural Gas
White Rodgers Mercury Flame Sensors

White Rodgers Mercury Flame Sensors

The mercury flame sensor is a mechanical device that proves the existence of an acceptable pilot flame. It converts
the heat of a pilot flame to motion which is used to open and close a set of electrical contacts, and consists of a bulb,
capillary, diaphragm, snap-switch mechanism, and mercury-fill. When the bulb is heated by a pilot flame, the mercury
is vaporized causing pressure in the capillary and diaphragm. Movement of the diaphragm causes the snap-switch to
open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve.
Features:
• Bulb styles are designed to fit with various OEM applications.
• Adapter fittings to allow use of these mercury flame sensors with competitive burners are packed with controls
identified with an asterisk(*).
• A.G.A. Design certified and C.G.A. Certified.
• Maximum temp. 1450°F at bulb tip.
White Rodgers Universal Nitride Hot Surface Upgrade Kit

White Rodgers Universal Nitride Hot Surface Upgrade Kit

Universal Silicon Nitride Igniter Upgrade Kit

Replaces over 100 silicon carbide igniters
Kit Includes:
• Nitride Ignitor with 15.5" Leads
• One “Universal” Mounting Bracket and Screw
• Mounting Adaptor Bracket
• 2 Ceramic Wire Nuts
• Updated Manufacturer Cross-Reference
• Nitride Upgrade Furnace Label
• Instruction Booklet
• Electrical Rating
• Input 102-132 VAC, 60Hz
• Max. Load Current 3.0 A @ 132 VAC, 25 degrees C
• Timing Rating 17 Seconds Minimum
Features:
• Robust Ignitor Design—
• for Longer Life and Fewer Callbacks
• Universal Bracket Fits Most Furnaces—
• Reduces Inventory
• Easy to Install
White Rodgers Universal Replacement Thermocouples

White Rodgers Universal Replacement Thermocouples

High temperature stainless steel element specially designed for universal replacement.
Features:
• Stainless steel element construction for prolonged thermocouple life.
• Each kit individually enclosed in plastic.
• Universal adapter fittings included with each kit for replacing thermocouple in most types of pilot burners.
• Visible instructions for quick, easy installation.
Conversion Kits- White-Rodgers Gas Valves

Conversion Kits for White-Rodgers Gas Valves
VR8204 Intermittent Pilot Dual Automatic Combination Gas Valves

VR8204 Intermittent Pilot Dual Automatic Combination Gas Valves

Combination gas controls for use in 24 VAC, gas-fired intermittent pilot appliances with capacities from 20 to 200 cfh.
• Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.
• Use with S86F,H; S8600F,H and S8610 control modules.
• Compact size.
• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
• Diaphragm operated second automatic valve opens under control of regulator; closes if gas or power supply is
interrupted.
• Meet codes requiring dual safety shutoff.
• Natural to LP gas conversion kits are available, but not included.
• All adjustments and wiring connections are accessible from top of control.
• VR8204 controls replace the following Honeywell and competitive combination gas controls for applications
requiring a minimum capacity of 20 cfh and a maximum capacity of 200 cfh.
— Honeywell VR8440
— White Rodgers 36E36/38
— Robertshaw 7100DER (700-070)
Approval Bodies:
American Gas Association Design certified: File No. L2025006.
Canadian Gas Association Design certified: File No. L2025006.
Mounting: 0° to 90° from the upright position of gas control knob, including vertically.
Body Pattern: Straight-through with 1/2" inlets and outlets.
Pressure Tapping: 1/8" NPT with plug.
Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure.
Pilot Gas Outlet: Compression fitting for 1/4" OD tubing.
Ambient Temperature Range:
VR8204A,C: 0°F to 175°F [-18°C to +79°C].
VR8204M: -40°F to +175°F [-40°C to +79°C].
Electrical Data:
Supply Voltage: 24 VAC, 60 Hz.
Wiring Connections: 1/4" male quick-connects.
Thermostat Heat Anticipator Setting: 0.5A.
On-Off lighting sequence.
White Rodgers 36C Replacement Gas Controls

White Rodgers 36C Replacement Gas Controls

Features:
• Valve may be mounted in any position, except upside down.
• Both main valve seat and line-interrupter seal with line pressure, assuring positive gas seal-off.
• Inlet screen, pilot gas filter and top operated main valve provide maximum protection against chips and dirt.
• Gas cock knob, pilot adjust screw and regulator adjustment are on top of control.
• Thermocouple connection on models with line interrupter and combination tab/screw terminals on 24 VAC models.
• Easy grip pipe boss simplifies installation. Built-in regulator system provides constant outlet pressure throughout entire usable capacity of valve, regardless of inlet pressure fluctuations.
• For use with all gases. (All models include LP Conversion kits.)
• Model 36C03 (24V) is for use with thermocouple (H06E Series, p. 99).
• Model 36C03U is for use with 750 millivolt power generator (S1-G01A-332, p. 99) and may be used with 250 millivolt system if nonanticipated room thermostat is used. Must be used in vented application.

Specifications
Regulator Setting: Natural gas, 3-1/2” W.C.
Regulator Adjustment Range: 2-1/2” to 5” W.C.
Ambient Operating Range: –40 to +175° F (–40 to +79° C)
Maximum Pressure Rating: 1/2 PSI (14.0” W.C.)
Pilot Gas Connection: 1/4” compression fitting furnished.
Pressure Tap: 1/8” NPT.
Body Pattern: Straight through.
White Rodgers 36C Step-Opening Complete Gas Valves With Natural/LP Gas Selector

White Rodgers 36C Step-Opening Complete Gas Valves With Natural/LP Gas Selector

24 VAC thermocouple-operated combination gas valve provides definite regulated step for smoother ignition of main burner.

Features:
• Step-opening main operator; valve initially opens to approximately 20% of rated flow for a minimum of two seconds, then fully opens.
• Gas selector (two positions: UP for natural, DOWN for LP) changes regulator setting from one gas to the other.
• Both main seat and flow-interrupter seal with line pressure, assuring positive gas seal-off.
• Inlet screen, pilot gas filter and top-operated main valve provide maximum protection against dirt and chips.
• Multipoise mounting (except upside-down).
• Easily accessible pilot-gas and pressure taps, combination tab-screw terminals and easy grip pipe boss simplify installation.
• A.G.A. design certified and C.G.A. Certified.

Specifications:
Electrical rating: 0.23 amps
Regulator setting: Natural gas, 3.5" W.C., LP
gas, 11.0" W.C.
Ambient operating range: –40° to +175° F (–40° to +79° C)
Maximum pressure rating: 1/2 PSI (14.0" W.C.)
Pilot gas connection: 1/4" compression fitting furnished
Pressure tap: 1/8" NPT
Swing radius: 4.5"
White Rodgers 36H Series Universal Fast Open High Capacity Gas Valves

White Rodgers 36H Series Universal Fast Open High Capacity Gas Valves

White Rodgers 36H valves are used for proven pilot applications, and can replace more than 93 valves in the 36C68/36C76 series. Improvements over the 36C series include: field convertible from Natural to LP, independently field adjustable two-stage regulators and electric on/off switch.

Features:
• 320K BTU at 1” pressure drop versus 280K BTU at 1” for the 36C series
• Diaphragm size increased 15% over 36C series resulting in improved regulation set point stability
• Quiet design, DC rectified
• Independently adjustable high/low two stage
• Direct ignition or proven pilot
• 24 volt, 50/60 Hz
• 0.75” x 0.75”; 0.25” press tap in and out
• 50k–400k BTU range of regulation
• Straight through design
White Rodgers 36J Series Universal Gas Valves

White Rodgers 36J Series Universal Gas Valves

The 36J combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition systems (Direct Spark Ignition, Hot Surface Ignition). Models include fast and slow open single and two stage valves. These valves are also convertible for natural/LP gases. Along with its
reduced size, all control adjustments and features, as well as the system interface-wiring panel, have been designed on the top surface of the control for simplified application and easy accessibility. The 36J gas control is designed to meet today’s requirement for maximum capacity, smaller size and highly efficient gas systems.

Features:
• Patented coaxial solenoid design.
• Inlet and optional outlet screens help protect from debris.
• Controlled gasket compression.
• Tamper resistant screws.
• Built-in hose connections for simplified field service or Std. 1/8” NPT (optional).
• Conveniently located electric on-off switch.
• Versatile mounting.
Sort By:
Page of 1
PART #: 02634710000 - PILOT BURNER PART #: 02920422056 - ORIFICE PILOT #56 (.0465) PART #: 02920423058 - BURNER ORIFICE #58 (.0421)
List Price: $40.28
Our Price: $22.54
Sale Price: $19.15
Savings: $21.13
Our Price: $4.70
Our Price: $4.02
PART #: S1-02634710000 PART #: S1-02920422056 PART #: S1-02920423058
PART #: 03109156000 - BOARD CONTROL FAN/ELECTRIC HEAT UT PART #: 21D64-2 - KIT IGNITOR UPGRADE SILICON NITRIDE W/R PART #: 21M51U-843 - KIT 2-STG FURNACE IFC 3-SPD PSC MOTOR UNIV
Our Price: $100.54
Sale Price: $85.45
Savings: $15.09
List Price: $70.64
Our Price: $43.80
Savings: $26.84
List Price: $446.39
Our Price: $276.76
Savings: $169.63
PART #: S1-03109156000 PART #: S1-21D64-2 PART #: S1-21M51U-843
PART #: 21V51U-843 - KIT 2-STG FURNACE IFC VAR SPD MOTOR UNIV PART #: 3049-18 - SENSOR FLAME MERCURY PART #: 3049-64 - SENSOR FLAME MERCURY
List Price: $446.39
Our Price: $276.76
Savings: $169.63
List Price: $310.26
Our Price: $173.74
Sale Price: $147.67
Savings: $162.59
List Price: $310.36
Our Price: $173.80
Sale Price: $147.73
Savings: $162.63
PART #: S1-21V51U-843 PART #: S1-3049-18 PART #: S1-3049-64
PART #: 3098-134 - SENSOR FLAME MERCURY PART #: 3098-156 - SENSOR FLAME MERCURY PART #: 30A46-5 - SENSOR FLAME MERCURY
Our Price: $234.14
Sale Price: $147.95
Savings: $86.19
Our Price: $234.14
List Price: $312.79
Our Price: $193.93
Savings: $118.86
PART #: S1-3098-134 PART #: S1-3098-156 PART #: S1-30A46-5
PART #: 32815537001 - KIT CONDENSER PAN 33 INCH 060 BTU PART #: 32816447000 - KIT CONDENSER PAN 33 INCH 060 BTU PART #: 36C03-300 - GAS VALVE
Our Price: $59.72
Sale Price: $55.50
Savings: $4.22
Our Price: $53.18
Our Price: $118.70
Sale Price: $77.51
Savings: $41.19
PART #: S1-32815537001 PART #: S1-32816447000 PART #: S1-36C03-300
PART #: 36C03-333 - GAS VALVE PART #: 36C03-400 - GAS VALVE PART #: 36C03-433 - GAS VALVE
Our Price: $117.62
Sale Price: $82.33
Savings: $35.29
Our Price: $126.98
Sale Price: $92.50
Savings: $34.48
Our Price: $159.60
Sale Price: $135.66
Savings: $23.94
PART #: S1-36C03-333 PART #: S1-36C03-400 PART #: S1-36C03-433
PART #: 36C03U-333 - GAS VALVE 750MV PART #: 36H32-304 - VALVE GAS NATURAL 1/2 X 3/4 24VAC PART #: 36H32-423 - VALVE GAS WHITE-RODGERS 36H32-423
Our Price: $169.32
Sale Price: $114.66
Savings: $54.66
Our Price: $152.98
Sale Price: $110.99
Savings: $41.99
Our Price: $161.16
Sale Price: $111.50
Savings: $49.66
PART #: S1-36C03U-333 PART #: S1-36H32-304 PART #: S1-36H32-423
PART #: 36H33-412 - VALVE GAS NATURAL 3/4 X 3/4 24VAC PART #: 36H64-463 - VALVE GAS WHITE-RODGERS 36H64-463 PART #: 36H65-401 - VALVE GAS NATURAL 3/4 X 3/4 24VAC
Our Price: $160.98
Sale Price: $108.99
Savings: $51.99
Our Price: $225.70
Sale Price: $140.00
Savings: $85.70
Our Price: $206.42
Sale Price: $146.85
Savings: $59.57
PART #: S1-36H33-412 PART #: S1-36H64-463 PART #: S1-36H65-401
PART #: 36J22-214 - VALVE GAS NATURAL 1/2 X 1/2 24VAC PART #: 36J24-214 - VALVE GAS NATURAL 1/2 X 1/2 24VAC PART #: 36J24-614 - VALVE GAS NATURAL 1/2 X 1/2 24VAC
Our Price: $82.14
Sale Price: $57.49
Savings: $24.65
Our Price: $91.14
Sale Price: $63.79
Savings: $27.35
Our Price: $85.84
Sale Price: $62.00
Savings: $23.84
PART #: S1-36J22-214 PART #: S1-36J24-214 PART #: S1-36J24-614
PART #: 36J54-214 - VALVE GAS NATURAL 1/2 X 1/2 24VAC PART #: 36J55-214 - VALVE GAS NATURAL 1/2 X 1/2 24VAC PART #: 36J55-614 - VALVE GAS NATURAL 1/2 X 1/2 24VAC
Our Price: $127.88
Sale Price: $92.50
Savings: $35.38
Our Price: $130.30
Sale Price: $93.50
Savings: $36.80
Our Price: $130.82
Sale Price: $93.75
Savings: $37.07
PART #: S1-36J54-214 PART #: S1-36J55-214 PART #: S1-36J55-614
PART #: 37306660000 - TUBE GAS PILOT PART #: 37C73U-168 - GAS VALVE PART #: 391936 - GAS CONVERTERSION LP TO N KIT HONEYWELL
Our Price: $24.62
List Price: $221.89
Our Price: $137.57
Savings: $84.32
List Price: $20.93
Our Price: $12.98
Savings: $7.95
PART #: S1-37306660000 PART #: S1-37C73U-168 PART #: S1-391936
PART #: 391937 - GAS CONVERTERERSION N TO LP KIT HONEYWELL PART #: 393691 - GAS CONVERSION N TO LP KIT HONEYWELL PART #: 393691-2 - GAS CONVERSION N TO LP KIT HONEYWELL
List Price: $14.14
Our Price: $8.77
Savings: $5.37
Our Price: $8.84
List Price: $18.21
Our Price: $11.29
Savings: $6.92
PART #: S1-391937 PART #: S1-393691 PART #: S1-393691-2
PART #: 394588 - GAS CONVERSION LP TO N KIT HONEYWELL PART #: 5059-23 - PILOT RELITE CONTROL PART #: 50A55-843 - UNIVERSAL INTEGRATED CONTROL
Our Price: $11.82
Sale Price: $9.97
Savings: $1.85
List Price: $192.46
Our Price: $112.57
Sale Price: $69.95
Savings: $122.51
Our Price: $153.32
Sale Price: $107.32
Savings: $46.00
PART #: S1-394588 PART #: S1-5059-23 PART #: S1-50A55-843
PART #: 50A65-843 - CONTROL GAS IGNITION PART #: 50D50-842 - CONTROL GAS IGNITION PART #: 50D50-843 - CONTROL GAS IGNITIONITION
Our Price: $162.82
Sale Price: $113.97
Savings: $48.85
List Price: $268.93
Our Price: $166.74
Savings: $102.19
List Price: $268.93
Our Price: $166.74
Savings: $102.19
PART #: S1-50A65-843 PART #: S1-50D50-842 PART #: S1-50D50-843
PART #: 50E47-843 - BOARD CONTROL HSI UNIVERSAL PART #: 50M56U-843 - KIT SGL STG FURNACE IFC UNIVERSAL PART #: 5D51-35 - LIMIT CONTROL 5 INCH ELEMENT
List Price: $271.43
Our Price: $168.29
Savings: $103.14
List Price: $298.89
Our Price: $185.31
Savings: $113.58
List Price: $188.29
Our Price: $116.74
Savings: $71.55
PART #: S1-50E47-843 PART #: S1-50M56U-843 PART #: S1-5D51-35
PART #: 5D51-78 - LIMIT CONTROL 11 INCH ELEMENT PART #: 5D51-90 - LIMIT CONTROL 8 INCH ELEMENT PART #: 9849-0161 - ROBERTSHAW PILOT BURNER
Our Price: $116.74
List Price: $188.29
Our Price: $116.74
Savings: $71.55
Our Price: $11.36
PART #: S1-5D51-78 PART #: S1-5D51-90 PART #: S1-9849-0161
PART #: F92-0656 - KIT VALVE CONVERTER (P) TO (N) PART #: F92-0659 - KIT VALVE CONVERTER (N) TO (P) PART #: G01A-332 - GENERATOR POWER 750 MILLIVOLT
List Price: $12.93
Our Price: $8.02
Savings: $4.91
List Price: $17.68
Our Price: $10.96
Savings: $6.72
List Price: $90.79
Our Price: $56.29
Savings: $34.50
PART #: S1-F92-0656 PART #: S1-F92-0659 PART #: S1-G01A-332
PART #: G01A-512 - GENERATOR 750V PART #: H06E-18 - THERMOCOUPLE 18" STAIN STEEL (M10) PART #: H06E-24 - THERMOCOUPLE 24" STAIN STEEL (M10)
List Price: $76.46
Our Price: $47.41
Savings: $29.05
List Price: $10.43
Our Price: $6.47
Savings: $3.96
List Price: $10.96
Our Price: $6.80
Savings: $4.16
PART #: S1-G01A-512 PART #: S1-H06E-18 PART #: S1-H06E-24
PART #: H06E-30 - THERMOCOUPLE 30" STAIN STEEL (M10) PART #: H06E-36 - THERMOCOUPLE 36" STAIN STEEL (M10) PART #: H06E-48 - THERMOCOUPLE 48" STAIN STEEL (M10)
List Price: $11.54
Our Price: $7.15
Savings: $4.39
List Price: $12.04
Our Price: $7.46
Savings: $4.58
List Price: $13.93
Our Price: $8.64
Savings: $5.29
PART #: S1-H06E-30 PART #: S1-H06E-36 PART #: S1-H06E-48
PART #: H06E-72 - THERMOCOUPLE 72" STAIN STEEL (M10) PART #: HSI-401 - IGNITER HOT SURF KIT 271A 4.5"LEAD (M12) PART #: HSI-402 - KIT IGNITER (HSI) 271W 19" LEAD (M12)
List Price: $21.21
Our Price: $13.15
Savings: $8.06
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
PART #: S1-H06E-72 PART #: S1-HSI-401 PART #: S1-HSI-402
PART #: HSI-403 - IGNITER HOT SURF KIT 271M 5.5"LEAD (M12) PART #: HSI-404 - IGNITER HOT SURF KIT 271M 4.5"LEAD (M12) PART #: HSI-405 - IGNITER HOT SURF KIT 271D 5.5"LEAD (M12)
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $20.35
Sale Price: $16.01
Savings: $24.88
PART #: S1-HSI-403 PART #: S1-HSI-404 PART #: S1-HSI-405
PART #: HSI-406 - IGNITER HOT SURF KIT 271Y 10.5"LEAD(M12) PART #: HSI-407 - IGNITER HOT SURF KIT 271 4.5"LEAD (M12) PART #: HSI-408 - IGNITER HOT SURF KIT 271N 4.5" LEAD(M12)
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
PART #: S1-HSI-406 PART #: S1-HSI-407 PART #: S1-HSI-408
PART #: HSI-409 - IGNITER HOT SURF KIT 271 4.5" LEAD (M12) PART #: HSI-410 - IGNITER HOT SURF KIT 271N 4.5"LEAD(M12) PART #: HSI-411 - IGNITER HOT SURF KIT 271N 4.5" LEAD(M12)
List Price: $40.89
Our Price: $25.35
Sale Price: $15.44
Savings: $25.45
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
PART #: S1-HSI-409 PART #: S1-HSI-410 PART #: S1-HSI-411
PART #: HSI-412 - IGNITER HOTSURF KIT 271NM 5.25"LEAD(M12) PART #: HSI-414 - IGNITER HOTSURF KIT 271NM 5.25"LEAD(M12) PART #: HSI-418 - IGNITER HOT SURFACE 271NM 5.25"LEAD(M12)
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
List Price: $40.89
Our Price: $25.35
Sale Price: $16.01
Savings: $24.88
PART #: S1-HSI-412 PART #: S1-HSI-414 PART #: S1-HSI-418
PART #: HSI-SN1 - IGNITER HOT SURF UNIV SIL NITRIDE (M10) PART #: HSIURK120VF -This item is no longer available But it is replace by S1-HSI-SN1 PART #: HSIURK120VR - This item is no longer available But it is replace by S1-HSI-SN1
List Price: $50.00
Our Price: $29.02
Sale Price: $20.30
Savings: $29.70
List Price: $72.54
Our Price: $44.97
Savings: $27.57
List Price: $57.89
Our Price: $25.89
Savings: $32.00
PART #: S1-HSI-SN1 PART #: S1-HSIURK120VF PART #: S1-HSIURK120VR
PART #: ICM303 - CONTROL DEFROST ICM303 PART #: ICM325HNV-LF - CONTROL PRESSURE HEAD W/HP BYPASS PART #: ICM326HM2 - CONTROL PRESSURE HEAD W/HP BYPASS
List Price: $133.50
Our Price: $77.00
Savings: $56.50
Our Price: $160.66
Sale Price: $112.46
Savings: $48.20
List Price: $355.96
Our Price: $220.70
Savings: $135.26
PART #: S1-ICM303 PART #: S1-ICM325HNV-LF PART #: S1-ICM326HM2
PART #: L4064B2236 - CONTROL FAN LIMIT PART #: L6006A1145 - TEMPERATURE CONTROLLER PART #: L8148A1017 - RELAY
Our Price: $120.46
Sale Price: $84.32
Savings: $36.14
List Price: $237.14
Our Price: $147.03
Savings: $90.11
List Price: $353.32
Our Price: $219.06
Savings: $134.26
PART #: S1-L4064B2236 PART #: S1-L6006A1145 PART #: S1-L8148A1017
PART #: L8148J1009 - RELAY PART #: Q313A1055 - THERMOPILE 47 INCH LEAD W/O ADAPTOR PART #: Q313A1139 - THERMOPILE 35 INCH LEAD
List Price: $411.82
Our Price: $255.33
Savings: $156.49
Our Price: $65.45
Sale Price: $48.42
Savings: $17.03
Our Price: $60.54
Sale Price: $42.18
Savings: $18.36
PART #: S1-L8148J1009 PART #: S1-Q313A1055 PART #: S1-Q313A1139
PART #: Q345A1305 - PILOT BURNER PART #: S8610U3009 - CONTROL GAS IGNITION INTERMITTENT PILOT PART #: SV9501M2528 - VALVE SMART NATURAL GAS
Our Price: $38.42
Sale Price: $30.49
Savings: $7.93
Our Price: $183.64
Sale Price: $114.00
Savings: $69.64
Our Price: $368.00
Sale Price: $239.20
Savings: $128.80
PART #: S1-Q345A1305 PART #: S1-S8610U3009 PART #: S1-SV9501M2528
PART #: SV9641M4510 - KIT VALVE GAS NATURAL SMART PART #: V800A1088 - GAS VALVE PART #: V800A1476 - GAS VALVE
Our Price: $352.00
Sale Price: $235.00
Savings: $117.00
Our Price: $265.22
Sale Price: $165.76
Savings: $99.46
Our Price: $235.62
Sale Price: $164.93
Savings: $70.69
PART #: S1-SV9641M4510 PART #: S1-V800A1088 PART #: S1-V800A1476
PART #: V800C1052 - GAS VALVE 3/4 X 3/4 WITH SIDE TAP PART #: V8043A1029 - ZONE VALVE 3/4" PART #: V8043E1004 - VALVE ZONE MOTORZED 24V 1/2 SWT LOW VOLT
Our Price: $473.78
Sale Price: $331.64
Savings: $142.14
Our Price: $105.82
Our Price: $113.11
PART #: S1-V800C1052 PART #: S1-V8043A1029 PART #: S1-V8043E1004
PART #: V8043E1012 - VALVE ZONE 3/4 2POS.NORM-CLOSE PART #: V8043E1020 - ZONE VALVE 1" 24V PART #: V8043E1061 - VALVE ZONE 3/4" 8CV 8PSI CLOSE
Our Price: $124.86
Our Price: $133.54
Our Price: $118.91
PART #: S1-V8043E1012 PART #: S1-V8043E1020 PART #: S1-V8043E1061
PART #: V8043F1036 - VALVE ZONE 3/4 2POS.NORM-CLOSE PART #: V8043F1051 - ZONE VALVE 2 POSITION NORMALLY CLOSED PART #: VR8200A2124 - GAS VALVE
Our Price: $141.65
Our Price: $156.59
Our Price: $133.50
Sale Price: $93.45
Savings: $40.05
PART #: S1-V8043F1036 PART #: S1-V8043F1051 PART #: S1-VR8200A2124
PART #: VR8200A2132 - VALVE GAS 1/2X1/2 PART #: VR8204A2027 - GAS VALVE Replacement S1-VR8345M4302 PART #: VR8204C1019 - GAS VALVE STEP OPENING NATURAL GAS
Our Price: $112.93
Our Price: $156.20
Sale Price: $105.00
Savings: $51.20
Our Price: $179.00
PART #: S1-VR8200A2132 PART #: S1-VR8204A2027 PART #: S1-VR8204C1019
PART #: VR8204M1026 - VALVE GAS NAT 1/2 X 1/2 INCH PART #: VR8205A2024 - HONEYWELL GAS VALVE PART #: VR8300A3500 - GAS CONTROL
Our Price: $176.48
Sale Price: $123.53
Savings: $52.95
Our Price: $136.11
Our Price: $131.06
PART #: S1-VR8204M1026 PART #: S1-VR8205A2024 PART #: S1-VR8300A3500
PART #: VR8300A4508 - STANDING PILOT GAS VALVE 3/4 X 3/4 PART #: VR8300A4516 - GAS CONTROL PART #: VR8304M3509 - GAS VALVE
Our Price: $160.00
Sale Price: $103.91
Savings: $56.09
Our Price: $156.31
Our Price: $168.71
PART #: S1-VR8300A4508 PART #: S1-VR8300A4516 PART #: S1-VR8304M3509
PART #: VR8304M4507 - GAS CONTROL PART #: VR8345M4302 - GAS VALVE NATURAL GAS
Our Price: $149.31
Our Price: $156.20
Sale Price: $105.00
Savings: $51.20
PART #: S1-VR8304M4507 PART #: S1-VR8345M4302