SC045 - T'STAT COOL ONLY FIXED SETPOINT 45F(M10)



The SC045 to SC075 series thermostats are low-cost, single setpoint thermostats intended for use as temporary devices to
provide heating or cooling to allow drywall to dry during construction. They also can be used as a low ambient cutoff switc

Features:

• Two-wire installation
• Six fixed setpoint models to choose from: 45oF to 75oF
• Temporary use for dryout applications
• Can be used as a low ambient cutoff switch

Specifications:

Input: 18-30 VAC
Output: 2 amp maximum
Temperature Control Range: 45°F to 75°F (±5°F)

Mode Of Operation
Heat/Cool Thermostat-
The heating models will close when the ambient temperature drops below the respective setpoint
and open when the ambient temperature is above the respective setpoint. The cooling models will close when the ambient
temperature is above the respective setpoint and open when the ambient temperature drops below the respective setpoint.

Low Ambient Cutoff: Condenser Fan Motor-
The SC045 and SC055 models can be used as a low ambient cutoff switch for
a condensor fan motor. When the ambient temperature drops below the setpoint, the unit will open the fan signal and turn the
fan motor off. It will not allow the fan to turn back on until the temperature rises above the setpoint.

Low Ambient Cutoff: Compressor-
The SC045 and SC055 models can also be used as a low ambient cutoff switch for the
compressor when wired in series with the Y circuit from the thermostat. When using with the compressor circuit, an anti-short
cycle timer is recommended to prevent possible damage to the compressor from short cycling.