Home > HVAC Components > ICM Furnace Control Modules - ICM284, CM287, ICM289, ICM291, ICM292, ICM2804

ICM Furnace Control Modules - ICM284, CM287, ICM289, ICM291, ICM292, ICM2804

• S1-ICM284 - LOW COST, DIRECT REPLACEMENT FURNACE CONTROL BOARD
• S1-ICM287 - LOW COST, DIRECT REPLACEMENT FURNACE CONTROL BOARD
• S1-ICM289 - LOW COST, DIRECT REPLACEMENT FURNACE CONTROL BOARD
• S1-ICM291 - LOW COST, DIRECT REPLACEMENT FOR CARRIER: LH33WP003A
• S1-ICM292 - LOW COST, DIRECT REPLACEMENT FOR RHEEM: 62-24140-04
• S1-ICM2804 - LOW COST, DIRECT REPLACEMENT FURNACE CONTROL BOARD > Note: This board functions identically as the CES0110074-00 and the CES0110074-01. It is a direct replacement of the CES0110074-01. When replacing the CES0110074-00 some quick connectors have to be changed or added. EAC-1 and EAC-2 must have 1/4” connectors. COM, SEC-1 and SEC-2 must have 3/16” connectors.
Sort By:
Page of 1
PART #: ICM2804 - BOARD CTRL IGNITION CARRIER REPLACES CES0110074-00 & CES0110074-01 PART #: ICM284 - MODULE CONTROL FURNACE REPLACES S1-03101280000
Usually Ships in 2 to 3 Business Days
Our Price: $147.40
Sale Price: $112.30
Savings: $35.10
Usually Ships in 2 to 3 Business Days
List Price: $645.96
Our Price: $294.91
Savings: $351.05
PART #: S1-ICM2804 PART #: S1-ICM284
Features:
• Hot Surface Ignition (HSI) control board
• Microprocessor-based
• Controls vent motor and blower control
• Monitors limit switch, pressure switch and gas valve
• 100% lockout safety feature
• Compatible with LP or Natural Gas
• Status LED for fault codes to aid in troubleshooting
• Replaces: Carrier CES0110074-00 and CES0110074-01
Specifications:
Environment
• Ambient Temperature
Operating: -40ºF to 176ºF
Storage: -40ºF to 185ºF
• Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF
• Vibration: 13.8Hz @ 0.2 Gs for one hour in each
orthogonal axis
Electrical
• Voltage Range: Line (98-132 VAC) @ 60Hz
• Cool Blower: 20A, 2 HP, 240 VAC
• Heat: 10A, 240 VAC
• Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
Timing
• Inducer Pre-Purge Time: 1 second
• Heat Blower On Delay: 45 seconds
• Heat Blower Off Delays: 120 or 180 seconds
• Cool Blower On Delay: 1 seconds
• Cool Blower Off Delay: 1 seconds

Note: This board functions identically as the CES0110074-00 and the CES0110074-01. It is a direct replacement of the CES0110074-01. When replacing the CES0110074-00 some quick connectors have to be changed or added. EAC-1 and EAC-2 must have 1/4” connectors. COM, SEC-1 and SEC-2 must have 3/16” connectors.
Features:
• Controls vent motor, blower control, hot surface ignitor and gas valve
• Microprocessor based
• Designed for 100% gas shutoff in case of ignition failure
• Monitors timing, trial for ignition, flame sensing and lockout
• Diagnostic LEDs aid in testing/troubleshooting
Specifications:
Electrical
• Line Voltage Range: 208 VAC @ 60Hz
• Ignitor: 5A resistive @ 208 VAC
• Cool Blower: 30 A, 2 HP, 240 VAC
• Heat Blower: 10 A, ½ HP, 250 VAC
• Inducer Motor: 4A, 208 VAC
• Gas Valve: 4A @ 24 VAC
• Compressor: 5A resistive @ 24 VAC
Environmental
• Ambient Temperature: Operating: -40°C to 80°C
Storage: -40°C to 85°C
• Humidity: 5% - 95% R.H. (non-condensing) at +55°C
Replaces:
• York: S1-03101280000
PART #: ICM287 - MODULE CONTROL FURNACE REPLACES GOODMAN B18099-04 PART #: ICM289 - MODULE CONTROL FURNACE LENNOX REPL
Usually Ships in 2 to 3 Business Days
List Price: $253.79
Our Price: $165.22
Savings: $88.57
Usually Ships in 2 to 3 Business Days
List Price: $282.04
Our Price: $183.60
Savings: $98.44
PART #: S1-ICM287 PART #: S1-ICM289
Features:
• Controls inducer and blower control
• Microprocessor based
• Designed for 100% gas shutoff in case of ignition failure
• Monitors timing and gas valve
• Diagnostic LEDs aid in testing/ troubleshooting
Specifications:
Electrical
• Line Voltage Range: 120 VAC @ 60Hz
• Control Voltage: 24 VAC @ 60 Hz
• Cool Blower: 30A resistive @ 120 VAC
• Heat Blower: 10A resistive @ 120 VAC
• Inducer Blower: 10A resistive @ 120 VAC
Environmental
• Ambient Temperature: Operating: -40°C to 80°C
Storage: -40°C to 85°C
• Humidity: 5% - 95% R.H. (non-condensing) at +55°C
Replaces:
• Goodman: B18099-04
Features:
• Low cost, direct replacement board for Lennox
• Microprocessor based design
• Controls inducer fan motor, blower fan and monitors limit switches
• Functions with all 24 VAC thermostats
Specifications:
• Voltage Range: Line (98 to 132 VAC) @ 60 Hz
• Cool Blower: 20A @ 120 VAC
• Heat Blower: 20A @ 120 VAC
• Inducer Motor: 5A @ 120 VAC
• Cool Blower On Delay: 1 second
• Cool Blower Off Delay: 1 second
• Heat Blower On Delay: 45 seconds
• Heat Blower Off Delay: 90, 150, 210, 270 seconds
Replaces:
• Lennox: Replaces all BCC1, BCC2 and BCC3 circuit boards, including models LB-53622A, BCC2-2REV8, 35K77,
35K7701, LB-90089A, 65K29, 65K2901, LB-50709BD, LB-65126A, LB-89859, LB-87086A, LB-87086, LB-63622AA,
LB-90676A, 40L8801, 30H6701, 48K98, 48K9801, 45K48, 45K4801, 78J61, 78J6101, 68H08.
PART #: ICM291 - BOARD CTRL IGNITION CARRIER REPLACEMENT LH33WP003A PART #: ICM292 - BOARD CTRL IGNITION RHEEM REPLACEMENT 62-24140-04
Usually Ships in 2 to 3 Business Days
Our Price: $231.64
Usually Ships in 2 to 3 Business Days
Our Price: $187.03
Sale Price: $122.87
Savings: $64.16
PART #: S1-ICM291 PART #: S1-ICM292
Features:
• Low cost, direct replacement for Carrier: LH33WP003A
• Direct Spark Ignition (DSI) control board
• Microprocessor-based
• Controls combustion, blower and indorr fan motors; spark ignitor; and the gas valve
• Monitors timing, trial for ignition, flame sensing and lockout
• 100% lockout safety feature
• Compatible with LP or Natural Gas
• Status LED for fault codes to aid in troubleshooting
Specifications:
• Control Voltage: 24 VAC (18-30 VAC), 60Hz
• Line Voltage: 208/230 VAC, 60Hz
Timing:
• Pre-Purge
• Trial for Ignition
• Retry Period
• Lockout
• Post-Purge
: 45 seconds
: 5+2 seconds
: Every 20 seconds for 15 minutes
: Manual reset
: 45 seconds
Input:
• Power: RT and C
• Thermostat Interface: R,W, and G
• Safety Switches: RS, LS, and CS
• Combustion Motor Hall Effect Sensor
• Flame Sensing
Outputs:
• Spark
• Gas Valve: GV
• Combustion Motor: CM
• Blower Motor: BM
• Indoor Fan Motor: IFO
LED Indicators:
Red LED: Steady ON-normal operation; Flashing-fault codes

LOW COST, DIRECT REPLACEMENT FOR CARRIER: LH33WP003A
Features:
• Low cost, direct replacement for Rheem: 62-24140-04
• Direct Spark Ignition (DSI) control
• Microprocessor-based
• Controls inducer motors, air cleaner (if equipped), humidifier (if equipped), spark ignitor, and the gas valve
• Monitors timing, trial for ignition, system switches, flame sesning, and lockout
• 100-percent lockout safety feature , Compatible with LP or Natural gas
• LED indication for status and fault codes to aid in troubleshooting
Specifications:
• Control Voltage: 24 VAC (18-30 VAC), 60Hz
• Line Voltage: 115 VAC, 60Hz
Timing:
Pre-Purge:
Trial for Ignition:
Retries:
Lockout:
Post-Purge:
30 seconds
7 seconds
Two groups of two, 30 second delay within the group, and 3 minute delay between groups
1-hour
90, 120, 160 and 180 seconds
Inputs:
• Power: 24 VAC and COM
• Thermostat Interface: R,W, Y, and G
• System Switches: Vent pressure and limit switches
• (main and over-temperature switches in series)
• Flame Sensing
• Heat Blower OFF Delay (miniature slide switch set)
Outputs:
• Spark
• Gas Valve: GV
• Inducer Draft Motor: IDM
• Blower Motor: FAN, COOL and HEAT speeds
• Electric air Cleaner: EAC
• Humidifier Relay: HUM , Heat/Cool Relay: H/C
LED Indicators:
• Power, Green LED: PWR
• Status, Green LED: OK
• Flame Status, Yellow LED: FLAME

LOW COST, DIRECT REPLACEMENT FOR RHEEM: 62-24140-04